SoTimeCounter Class Reference
[Engines]

Timed integer counter. More...

#include <Inventor/engines/SoTimeCounter.h>

Inheritance diagram for SoTimeCounter:
SoEngine SoFieldContainer SoBase SoRefCounter SoTypedObject

List of all members.

Classes

struct  Stage

Public Member Functions

virtual SoType getTypeId () const
 SoTimeCounter ()

Static Public Member Functions

static SoType getClassTypeId ()

Public Attributes

SoSFShort min
SoSFShort max
SoSFShort step
SoSFBool on
SoSFFloat frequency
SoMFFloat duty
SoSFTime timeIn
SoSFTrigger syncIn
SoSFShort reset
SoEngineOutput output
SoEngineOutput syncOut

Detailed Description

Timed integer counter.

This engine is a counter that outputs numbers, starting at a minimum value, increasing by a step value, and ending with a number that does not exceed the maximum value. When the maximum number is reached, it starts counting from the beginning again.

The difference between this engine and the SoCounter engine, is that this engine also has a timeIn input, which allows the counting cycles to be timed. This engine counts automatically over time; it does not need to be triggered to go to the next step. By default, the timeIn input is connected to the realTime global field. It can, however, be connected to any time source.

The frequency input field controls how many min-to-max cycles are performed per second. For example, a frequency value of 0.5 means that it will take 2 seconds to complete a single min-to-max cycle.

The steps in the count cycle do not necessarily all have the same duration. Using the duty input field, you can arbitrarily split the time period of the count cycle between the steps. For example, if there are 5 steps in the cycle, a duty input of (1., 2., 2., 2., 1.) will make the second, third, and fourth steps take twice as long as the first and last steps.

At any time the counter can be reset to a specific value. If you set the reset input field to a value, the engine will continue counting from there. Note that the counter will always output numbers based on the min, max and step values, and setting the reset value does not affect the those input fields. If the reset value is not a legal counter value, the counter will still behave as though it is:

Each time a counting cycle is started, the syncOut output is triggered. This output can be used to synchronize some other event with the counting cycle. Other events can also synchronize the counter by triggering the syncIn input.

You can pause the engine, by setting the on input to FALSE, and it will stop updating the output field. When you turn off the pause, by setting on to TRUE, it will start counting again from where it left off.

FILE FORMAT/DEFAULT

SEE ALSO

SoCounter, SoElapsedTime, SoEngineOutput

See related examples:

MedicalDentalCurveUnfolding


Constructor & Destructor Documentation

SoTimeCounter::SoTimeCounter (  ) 

Constructor.


Member Function Documentation

static SoType SoTimeCounter::getClassTypeId (  )  [static]

Returns the type identifier for this class.

Reimplemented from SoEngine.

virtual SoType SoTimeCounter::getTypeId (  )  const [virtual]

Returns the type identifier for this specific instance.

Implements SoTypedObject.


Member Data Documentation

Duty cycle values.

Number of min-to-max cycles per second.

Maximum value for the counter.

Minimum value for the counter.

Counter pauses if this is set to FALSE.

( SoSFShort ) Counts min-to-max, in step increments.

Reset the counter to the specified value.

Counter step value.

Restart at the beginning of the cycle.

( SoSFTrigger ) Triggers at cycle start.

Running time.


The documentation for this class was generated from the following file:

Open Inventor Toolkit reference manual, generated on 15 Mar 2023
Copyright © Thermo Fisher Scientific All rights reserved.
http://www.openinventor.com/