SoOneShot Class |
Timer that runs for a pre-set amount of time.
Namespace: OIV.Inventor.Engines
The SoOneShot type exposes the following members.
Name | Description | |
---|---|---|
Copy | Creates and returns an exact copy of the engine. | |
CopyFieldValues(SoFieldContainer) | Calls CopyFieldValues(fc, false). (Inherited from SoFieldContainer.) | |
CopyFieldValues(SoFieldContainer, Boolean) | Copies the contents of fc's fields into this object's fields. | |
Dispose |
Releases all resources used by SoDisposable.
(Inherited from SoDisposable.) | |
EnableNotify | Notification at this Field Container is enabled (if flag == true) or disabled (if flag == false). | |
Equals | Determines whether the specified Object is equal to the current Object. (Inherited from Object.) | |
FieldsAreEqual | Returns true if this object's fields are exactly equal to fc's fields. | |
Get | Returns the values of the fields of this object in the Open Inventor ASCII file format in the given string. | |
GetAllFields | Returns a list of fields, including the eventIn's and eventOut's. | |
GetEventIn | Returns a the eventIn with the given name. | |
GetEventOut | Returns the eventOut with the given name. | |
GetField | Returns a the field of this object whose name is fieldName. | |
GetFieldName | Returns the name of the given field in the fieldName argument. | |
GetFields | Appends references to all of this object's fields to resultList, and returns the number of fields appended. | |
GetHashCode |
Overrides GetHashCode().
(Inherited from SoNetBase.) | |
GetName | Returns the name of an instance. | |
GetOutput | Returns a reference to the engine output with the given name. | |
GetOutputName | Returns (in outputName) the name of the engine output (output). | |
GetOutputs | Returns a list of outputs in this engine. | |
GetStringName | (Inherited from SoBase.) | |
GetType | Gets the Type of the current instance. (Inherited from Object.) | |
HasDefaultValues | Returns true if all of the object's fields have their default values. | |
IsNotifyEnabled | Notification is the process of telling interested objects that this object has changed. | |
IsSynchronizable | Gets the ScaleViz synchronizable state of this object. | |
Set | Sets one or more fields in this object to the values specified in the given string, which should be a string in the Open Inventor file format. | |
SetName | (Inherited from SoBase.) | |
SetSynchronizable | Sets this to be a ScaleViz synchronizable object. | |
SetToDefaults | Sets all fields in this object to their default values. | |
ToString |
Converts this SoBase structure to a human readable string.
(Inherited from SoBase.) | |
Touch | Marks an instance as modified, simulating a change to it. |
Name | Description | |
---|---|---|
disable | If true, the timer is disabled. | |
duration | Duration of the active cycle. | |
flags | Control flags. | |
isActive | ( OIV.Inventor.Fields.SoSFBool ) Is true during the active cycle. | |
IsDisposable | ISafeDisposable interface implementation.
(Inherited from SoDisposable.) | |
ramp | ( OIV.Inventor.Fields.SoSFFloat ) Ramps linearly from 0.0 to 1.0. | |
timeIn | Running time. | |
timeOut | ( OIV.Inventor.Fields.SoSFTime ) Elapsed time from the start. | |
trigger | Start the cycle. | |
UserData |
Gets or sets the user data to be contained by the field container.
(Inherited from SoFieldContainer.) |
This engine is a timer that runs for a pre-set amount of time and then stops. By default, the OIV.Inventor.Engines.SoOneShot.timeIn input is connected to the realTime global field. It can, however, by connected to any other time source.
The timer is started when the OIV.Inventor.Engines.SoOneShot.trigger input is touched. It then runs for the specified OIV.Inventor.Engines.SoOneShot.duration, and updates the OIV.Inventor.Engines.SoOneShot.timeOut output with the time that has elapsed. During that time, the OIV.Inventor.Engines.SoOneShot.ramp output is also updated. The OIV.Inventor.Engines.SoOneShot.ramp output starts at 0.0 at the beginning of the cycle, and linearly increases until it reaches 1.0 at the end of the cycle.
You can disable the timer by setting the OIV.Inventor.Engines.SoOneShot.disable input to true. The output value remains 0.0 while the timer is disabled. If the timer is disabled in the middle of a cycle the output values will be set to 0.0.
The OIV.Inventor.Engines.SoOneShot.flags input contains control flags. Using the flags you can set the timer to be retriggerable in the middle of a cycle, and set the output values to stay high after the cycle has been completed. By default, these flags are not set.
OneShot {
duration | 1 |
trigger | |
flags | () |
disable | false |
timeIn | <current time> |