SoVRDicomFileReader Methods |
The SoVRDicomFileReader type exposes the following members.
Name | Description | |
---|---|---|
CloseAllHandles | Close all file handles currently opened by the reader. | |
CopyFieldValues(SoFieldContainer) | Calls CopyFieldValues(fc, false). (Inherited from SoFieldContainer.) | |
CopyFieldValues(SoFieldContainer, Boolean) | Copies the contents of fc's fields into this object's fields. | |
Dispose |
Releases all resources used by SoDisposable.
(Inherited from SoDisposable.) | |
EnableNotify | Notification at this Field Container is enabled (if flag == true) or disabled (if flag == false). | |
Equals | Determines whether the specified Object is equal to the current Object. (Inherited from Object.) | |
FieldsAreEqual | Returns true if this object's fields are exactly equal to fc's fields. | |
Get | Returns the values of the fields of this object in the Open Inventor ASCII file format in the given string. | |
GetAllFields | Returns a list of fields, including the eventIn's and eventOut's. | |
GetBorderFlag | Obsolete. (Inherited from SoVolumeReader.) | |
GetConfiguredWriter | (Inherited from SoVolumeReader.) | |
GetCoordinateType | Returns coordinate type used by the data set. | |
GetDataChar | Gets the characteristics (file header) of the data volume. | |
GetDicomData | Returns an instance of OIV.VolumeViz.Readers.SoVRDicomData for the first image of this volume. | |
GetDicomDataSet | Returns a DICOM data object for the specified slice containing all the DICOM attributes. | |
GetDirectCoordSys | Return whether the coordinate system used is direct or not. | |
GetDirectCoordSysAutoDetection | Return automatic detection value. | |
GetEventIn | Returns a the eventIn with the given name. | |
GetEventOut | Returns the eventOut with the given name. | |
GetField | Returns a the field of this object whose name is fieldName. | |
GetFieldName | Returns the name of the given field in the fieldName argument. | |
GetFields | Appends references to all of this object's fields to resultList, and returns the number of fields appended. | |
GetFilename | Returns the path of the file. | |
GetHashCode |
Overrides GetHashCode().
(Inherited from SoNetBase.) | |
GetHistogram(IListInt64) | Returns histogram if available. | |
GetHistogram(Queue) | Obsolete.
Returns histogram if stored in file.
(Inherited from SoVolumeReader.) | |
GetMinMax(Double, Double) | Returns min max for float data type, if available. | |
GetMinMax(Int32, Int32) | Obsolete. (Inherited from SoVolumeReader.) | |
GetMinMax(Int64, Int64) | Returns min and max for integer data type, if available. | |
GetName | Returns the name of an instance. | |
GetNumSignificantBits | This method is optional. | |
GetNumVoxels | Utility function provided by OIV.LDM.Readers.SoVolumeReader for subclass readers to call. | |
GetOriginalFilename | Returns original file name from which the data has been converted to LDM format if stored in file. | |
GetReaderType | Returns the reader type. | |
GetRectilinearCoordinates | Returns the coordinates for the specified axis. | |
GetSizeToAllocate | Utility function provided by OIV.LDM.Readers.SoVolumeReader for subclass readers to call. | |
GetStringName | (Inherited from SoBase.) | |
GetSubSlice(SbBox2i32, Int32, SoBufferObject) | Same as OIV.LDM.Readers.SoVolumeReader.GetSubSlice(OIV.Inventor.SbBox2i32, System.Int32, OIV.Inventor.Generic.SbNativeArray{{System.Byte}}) but using an OIV.Inventor.Devices.SoBufferObject as the target of the data. | |
GetSubSlice(SbBox2i32, Int32, SbNativeArrayByte) | Must copy the rectangular part defined by subSlice of the XY slice sliceNumber to the memory referenced by data. | |
GetTileMinMax | Returns the minimum and maximum data values for the given tile. | |
GetTileSize | Returns tile dimensions in voxels when using data stored in tiles. | |
GetType | Gets the Type of the current instance. (Inherited from Object.) | |
HasDefaultValues | Returns true if all of the object's fields have their default values. | |
IsIgnoredFile | Should return true if at least one file has been ignored during reading. | |
IsNotifyEnabled | Notification is the process of telling interested objects that this object has changed. | |
IsSynchronizable | Gets the ScaleViz synchronizable state of this object. | |
LoadInMemory | Load the DICOM data into contiguous memory if possible. | |
LoadSliceDicomData | Loads the Dicom data of the given slice. | |
ReadTile(Int32, SbBox3i32) | Given an index, reads a tile if the data is organized in tiles (for LDM). | |
ReadTile(Int32, SoBufferObject, SbBox3i32) | Obsolete. Same as OIV.LDM.Readers.SoVolumeReader.ReadTile(System.Int32, OIV.Inventor.Generic.SbNativeArray{{System.Byte}}, OIV.Inventor.SbBox3i32) but using an OIV.Inventor.Devices.SoBufferObject (allocated by LDM) as the target of the data. | |
ReadTile(Int32, SbNativeArrayByte, SbBox3i32) | Obsolete. Given an index, reads a tile if the data is organized in tiles (for LDM). | |
ReadXSliceInTile | Read directly from the data source, an orthoslice on the X axis (Zaxis == 0) inside a tile. | |
ReadXTraceInTile | Read directly from the data source, a trace inside a tile. | |
ReadYSliceInTile | Read directly from the data source, an orthoslice on the Y axis (Zaxis == 1) inside a tile. | |
ReadZSliceInTile | Read directly from the data source, an orthoslice on the Z axis (Zaxis == 2) inside a tile. | |
ReloadTileMinMax | (Inherited from SoVolumeReader.) | |
RestoreAllHandles | Restore all file handles closed by closeAllHandles method. | |
Set | Sets one or more fields in this object to the values specified in the given string, which should be a string in the Open Inventor file format. | |
SetDirectCoordSysAutoDetection | Sets whether or not the reader should automatically try to detect if the coordinate system used is direct or not. | |
SetDirectCoorSys | Specify if the coordinate system used is direct or not. | |
SetDirectory | Specify a directory containing DICOM files to load. | |
SetFilename | Specify the name of a DICOM file or a file containing a list of DICOM files to load. | |
SetFilenameList(IListString) |
Specifies the list of a DICOM files to load.
| |
SetFilenameList(String) | Calls SetFilenameList(format, System.Int32(0), INT_MAX, 1). | |
SetFilenameList(String, Int32) | Calls SetFilenameList(format, startIndex, INT_MAX, 1). | |
SetFilenameList(String, Int32, Int32) | Calls SetFilenameList(format, startIndex, endIndex, 1). | |
SetFilenameList(String, Int32, Int32, Int32) | Specify a list of DICOM files to load, using a sprintf-like format. | |
SetFilenameListFromSeries | Specify a DICOM file and load all image files in the same directory that are part of the same "series" based on the series UID (0x0020,0x000E). | |
SetFilenamePattern | Specify a pattern of DICOM files to load. | |
SetInputDataRange | Requests that the input be converted from the specified range to the range depending on the output data type. | |
SetName | (Inherited from SoBase.) | |
SetOutputDataType | Requests that the input be converted (if necessary) to the specified data type. | |
SetRectilinearCoordinates | Sets rectilinear coordinates for the data set. | |
SetSynchronizable | Sets this to be a ScaleViz synchronizable object. | |
SetToDefaults | Sets all fields in this object to their default values. | |
SetUserData | Obsolete.
Stores the userData (for example the filename string) in the m_data protected variable.
(Inherited from SoVolumeReader.) | |
ToString |
Converts this SoBase structure to a human readable string.
(Inherited from SoBase.) | |
Touch | Marks an instance as modified, simulating a change to it. |